Variable Shot
This is accomplished through the use of 2
independently controlled stepper motors.
-
No tools needed
-
No dials to adjust
-
No mistakes
One motor adjusts the shot volume by
changing the angle of the FMI Pump Head
lengthening or shortening the stroke of the
pump.
The second motor controls the FMI Valveless
Pump, dispense speed and frequency of the
shot.
Operation
The valveless pumping function is
accomplished by the synchronous rotation and
reciprocation of the ceramic piston in the
precisely mated ceramic cylinder liner
-
see animation on
top left of page.
One complete piston revolution is required
for each suction/discharge cycle.
Control
Controlling the pump
is easy with the XL Controller. Set
the shot volume, number of shots, and
dispense speed on the easy to use display.
100 stored programs let the operator change
setups on the fly without reprogramming or
adjusting anything. |